Single molecule localization microscopy with autonomous feedback loops for ultrahigh precision

Simao Coelho, Jongho baek, Matthew S Graus, James M Halstead, Philip R Nicovich, Kristen Feher, Hetvi Gandhi, Katharina Gaus

Preprint posted on December 05, 2018 https://www.biorxiv.org/content/biorxiv/early/2018/12/05/487728.full.pdf

Nanometer-accurate active drift correction for optical microscopy means crisper super-resolution images and allows ultra-precise distance measurements.

Selected by Sam Barnett

Categories: biophysics

Background

The long acquisition time required for localization microscopy to create an image leads to a number of complications such as drift. When drift occurs the sample’s apparent position on the camera sensor changes over time, leading to a “smearing” effect in the final image. Most solutions to this problem involve correcting the drift post-acquisition through cross-correlation or through tracking the drift with a stationary fiducial marker. This can lead to errors through imperfect correction and is also limited by the brightness of the fiducial. There is also the further potential loss of data if the sample drifts out of the cameras field of view.

 

Key findings

The authors have developed a real-time drift correction system in hardware that dampens the effects of drift in the microscope over long acquisitions. This is accomplished through non-fluorescent polystyrene beads that are embedded in the sample and illuminated with an infrared LED. The beads produce diffraction rings that are imaged onto a separate CMOS camera and used to actively correct drift, holding the sample stationary. As the diffraction rings do not result from fluorescence but rather scattering, high illumination powers can be used to acquire large numbers of photons without risk of photobleaching, allowing localization with nanometer precision. Drift can also occur as a result of motions in the optical components between the sample and the camera. The authors solved this by introducing a white LED that is focused to a spot on the camera to monitor and correct for changes in the emission light path. Analysis of sample drift allows the authors to reduce the drift in x,y, and z over an acquisition from 45 nm to 0.27 nm, an approximately 20 times reduction.

 

The authors went on to demonstrate the utility of their system in several biological contexts, such as imaging single actin filaments in vivo with a precision ranging from 5-9 nm. Importantly this was achieved without averaging the positions of localizations that are assumed to be the same molecule, a process that is typically used to increase the accuracy in localization microscopy. The authors also used their feedback system to investigate the membrane distribution of two proteins in T-cells to show the phosphatase CD45 is excluded from the phosphorylated CD3ζ nanoclusters. This mechanism of correcting drift is going to be essential for obtaining accurate <10 nm distance measurements between objects.

 

My thoughts

Whilst methods for correcting data post-acquisition are available and commonly used in localization analysis, the results are not always satisfactory. The post-experiment nature also limits the ability to assess the quality of the data as it is collected at the microscope. The authors’ method here takes the adage “prevention is better than the cure” to heart, meaning that scientists no longer have to worry that data from samples they have spent large amounts of time producing are not corrupted by motions during the acquisition. Ultimately, I would like to see a mechanism such as this introduced into commercial microscopes as it would vastly increase the quality of collected data and improve the reliability of experiments.

 

Questions to the authors:

1) One of the mechanisms for improving the drift correction was correcting the EMCCD camera although the details of this are not very well fleshed out. Can you elaborate more on what these corrections are and what purpose they are performing?

2) Further to this, CMOS cameras show more complicated noise statistics than EMCCD cameras. Have you tried applying gain and offset correction algorithms for correcting the sensor before fitting the diffraction rings?

Tags: microscopy, super-resolution

Posted on: 10th January 2019

Read preprint (1 votes)




  • Have your say

    Your email address will not be published. Required fields are marked *

    This site uses Akismet to reduce spam. Learn how your comment data is processed.

    Sign up to customise the site to your preferences and to receive alerts

    Register here

    Also in the biophysics category:

    The autophagic membrane tether ATG2A transfers lipids between membranes

    Shintaro Maeda, Chinatsu Otomo, Takanori Otomo



    Selected by Sandra Malmgren Hill

    Effective concentrations enforced by intrinsically disordered linkers are governed by polymer physics

    Charlotte S. Sørensen, Magnus Kjaergaard



    Selected by Tessa Sinnige

    1

    Spreading of molecular mechanical perturbations on linear filaments

    Zsombor Balassy, Anne-Marie Lauzon, Lennart Hilbert



    Selected by Lars Hubatsch

    Blue light induces neuronal-activity-regulated gene expression in the absence of optogenetic proteins

    Kelsey M. Tyssowski, Jesse M. Gray



    Selected by Zheng-Shan Chong

    HIV-1 Gag specifically restricts PI(4,5)P2 and cholesterol mobility in living cells creating a nanodomain platform for virus assembly

    C. Favard, J. Chojnacki, P. Merida, et al.



    Selected by Amberley Stephens

    Microfluidic protein isolation and sample preparation for high resolution cryo-EM

    Claudio Schmidli, Stefan Albiez, Luca Rima, et al.



    Selected by David Wright

    ENDOSOMAL MEMBRANE TENSION CONTROLS ESCRT-III-DEPENDENT INTRA-LUMENAL VESICLE FORMATION

    Vincent Mercier, Jorge Larios, Guillaume Molinard, et al.



    Selected by Nicola Stevenson

    1

    Planar differential growth rates determine the position of folds in complex epithelia

    Melda Tozluoğlu, Maria Duda, Natalie J Kirkland, et al.

    AND

    Buckling of epithelium growing under spherical confinement

    Anastasiya Trushko, Ilaria Di Meglio, Aziza Merzouki, et al.



    Selected by Sundar Naganathan

    2

    Microtubules stabilize intercellular contractile force transmission during tissue folding



    Selected by Ivana Viktorinová

    Dynamic Aha1 Co-Chaperone Binding to Human Hsp90

    Javier Oroz, Laura J Blair, Markus Zweckstetter



    Selected by Reid Alderson

    1

    A DNA-based voltmeter for organelles

    Anand Saminathan, John Devany, Kavya S Pillai, et al.



    Selected by Robert Mahen

    1

    Central spindle microtubules are strongly coupled to chromosomes during both anaphase A and anaphase B

    Che-Hang Yu, Stefanie Redemann, Hai-Yin Wu, et al.



    Selected by Federico Pelisch

    1

    Mechanical Stretch Kills Transformed Cancer Cells

    Ajay Tijore, Mingxi Yao, Yu-Hsiu Wang, et al.



    Selected by Joseph Jose Thottacherry

    Super-resolution Molecular Map of Basal Foot Reveals Novel Cilium in Airway Multiciliated Cells

    Quynh Nguyen, Zhen Liu, Rashmi Nanjundappa, et al.



    Selected by Robert Mahen

    Force inference predicts local and tissue-scale stress patterns in epithelia

    Weiyuan Kong, Olivier Loison, Pruthvi Chavadimane Shivakumar, et al.



    Selected by Sundar Naganathan

    Single molecule localization microscopy with autonomous feedback loops for ultrahigh precision

    Simao Coelho, Jongho Baek, Matthew S Graus, et al.



    Selected by Lars Hubatsch
    Close